How to Read a Certificate of Analysis (COA)
A Certificate of Analysis (COA) is the single best tool you have for judging a research compound before you buy it. But a COA only helps if you know how to read it. This guide walks through a real report line by line, explains what each type of lab test shows, and gives you a checklist for spotting a COA you shouldn’t trust.
Key takeaways
- 1A COA is a lab’s written record of what it tested, how it tested it, and what it found, for one specific batch.
- 2The most important lines are the lab’s name, the batch (lot) number, the claim vs the result, the method and the date.
- 3Purity tells you how much of the sample is the target compound. Concentration tells you how much is in each millilitre. They are different numbers.
- 4A COA should match your bottle. If the batch code on your label isn’t on the report, the report doesn’t prove anything about your bottle.
What is a COA?
Think of it as a receipt from the lab. A supplier can write anything on a label, but a COA from an independent lab is evidence from a third party that has no reason to flatter the product. That’s why serious suppliers publish them, and why you should read them rather than just check that one exists.
At Chemyo Labs, every published report lives in our Lab Reports library, searchable by compound or batch code. The examples in this guide come straight from that library.
Anatomy of a COA
Below is a simplified copy of a real Chemyo concentration report for batch BA2166. The numbered markers point to the parts you should check every time.
Tel: 714-398-8166 · info@nutrianalytical.com
| Test ID# | Lot# | Claim | Result |
|---|---|---|---|
| 202512005-7 | BA2166 #1 | 10 | 10.03 |
| 202512005-8 | BA2166 #2 | 10 | 10.18 |
| 202512005-9 | BA2166 #3 | 10 | 10.15 |
| + 5 more bottles | |||
- 1The lab’s identityA real lab name, street address, phone and email. You should be able to look the lab up independently.
- 2Client and datesWho submitted the sample, when the lab received it, and when it reported. The report date should make sense for the batch you’re buying.
- 3Sample descriptionWhat the lab was told the sample is, including the labelled strength.
- 4Test ID and lot numberThe test ID is the lab’s own reference. The lot number is the batch code that should match your bottle.
- 5Claim, result and methodWhat the label says, what the lab measured, and the technique used to measure it.
- 6SignatureA named person at the lab who is accountable for the results.
You can open the full, original BA2166 report in our library: view the BA2166 report.
Reading the numbers
The heart of any COA is the comparison between the claim (what the label says) and the result (what the lab measured). To judge how close they are, work out the difference as a percentage of the claim:
Example: (10.22 − 10) ÷ 10 × 100 = +2.2%
For batch BA2166, the lab tested eight separate bottles. Here’s what the full set of results tells you:
Two things make this a strong result. First, every bottle is close to the claim. Second, the bottles are close to each other, which shows the batch is consistent. A report that tests only one bottle can’t show you the second point, so multi-bottle testing is worth looking for.
Purity vs concentration
These two words get mixed up all the time, but they answer different questions:
“How much of this is the right compound?”
Purity is reported as a percentage, such as “>99%”. It tells you how much of the tested material is the target compound rather than something else.
Example from our library: a purity COA showing a claim of >99% and a result of 100.00% by UHPLC, plus an identification line marked “Conform”.
“How much is in each millilitre?”
Concentration applies to solutions and is reported in units like mg/ml. It tells you whether the solution was made up to the strength on the label.
Example from our library: batch BA2166, labelled 10 mg/ml, measured at 10.03 to 10.22 mg/ml across eight bottles.
A high-purity compound can still be made into a solution at the wrong strength, and a solution at the right strength can be made from impure material. That’s why the best reports cover identity, purity and concentration.
COA, HPLC, FTIR and spectral reports
In our library you’ll see several report types. Each one answers a different question about the batch:
Certificate of Analysis
The lab’s summary: what was tested, the method, the claim and the result. Start here.
Chromatogram
- Retention time: when the compound comes off the column, used to identify it against a reference.
- Peak area %: the share of the signal from the main peak, used to estimate purity. One tall, clean peak is what you want to see.
Infrared fingerprint
FTIR produces a pattern of peaks that is unique to a molecule, like a fingerprint. If the sample’s pattern matches the reference pattern, the identity is confirmed.
Spectral library match
Compares the light-absorption spectrum of the main HPLC peak against a spectral library. A close match adds a second, independent identity check.
You’ll also see reports marked “Retest”. A retest is an additional round of testing on a batch that was already tested, done to re-confirm its results.
8-point COA checklist
Run through these eight checks on any COA, from any supplier:
- The lab is named, with a real address and contact details
- The lab is independent, not the seller’s own in-house lab
- The report shows a batch or lot number
- That batch number matches the label on your bottle
- Both a claim and a measured result are shown
- The test method is stated (e.g. HPLC, UHPLC, FTIR)
- Received and report dates are shown and make sense
- The report is signed by a named person at the lab
Signs of a fake or useless COA
Be cautious if you see any of these
- No lab name, or a lab you can’t find anywhere online
- No batch number, or the same report used for every batch
- Results only, with no claim to compare them against
- No test method stated
- Very old report dates for a supposedly new batch
- Blurry or cropped images that hide the header or signature
- Fonts, alignment or numbers that look edited
When in doubt, you can contact the laboratory directly with the test ID from the report and ask whether it issued that report. A genuine report will hold up; a fake one won’t.
How to check a Chemyo COA in 3 steps
Find your batch code
It’s printed on your bottle’s label and starts with BA, for example BA2166.
Search our library
Type the batch code into the search box on our Lab Reports page.
Open and compare
Open the report and check the lot number, claim and result against your label.
Want to know more about how we choose labs and what we test for? Read about our quality control process, or see our guide Is Chemyo Legit?
Frequently asked questions
What does COA stand for?
COA stands for Certificate of Analysis: a document from a testing laboratory that records which tests were run on a sample, the methods used and the results found.
What is the difference between purity and concentration?
Purity, shown as a percentage, tells you how much of the tested material is the target compound. Concentration, shown in units like mg/ml, tells you how much of the compound is in each millilitre of a solution.
What is a good deviation from the label claim?
Smaller is better, and consistency across bottles matters as much as any single result. In the BA2166 example, all eight bottles were within 3% of the 10 mg/ml claim.
Why should the batch number match my bottle?
A COA describes one specific batch. If your bottle’s batch code isn’t on the report, the report doesn’t tell you anything about what’s in your bottle.
What does “Retest” mean on a report?
A retest is an additional round of testing on a batch that was already tested, done to re-confirm its results.
Can I verify a COA with the lab?
Yes. Contact the laboratory named on the report, quote the test ID, and ask whether it issued that report.
Put it into practice
Open any report in our library and run through the 8-point checklist yourself.
All Chemyo Labs products are sold strictly for laboratory research use only. They are not drugs, supplements or food, and are not for human or animal consumption.